Search results for "Electron multiplier"
showing 10 items of 18 documents
A Time Projection Chamber with GEM-Based Readout
2016
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
The COMPASS Setup for Physics with Hadron Beams
2015
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successful…
The upgrade of the ALICE TPC with GEMs and continuous readout
2020
Journal of Instrumentation 16(03), P03022 (2021). doi:10.1088/1748-0221/16/03/P03022
Time performance of a triple-GEM detector at high rate
2020
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification s…
Charge radii and electromagnetic moments of At195–211
2018
Hyperfine-structure parameters and isotope shifts of At195-211 have been measured for the first time at CERN-ISOLDE, using the in-source resonance-ionization spectroscopy method. The hyperfine structures of isotopes were recorded using a triad of experimental techniques for monitoring the photo-ion current. The Multi-Reflection Time-of-Flight Mass Spectrometer, in connection with a high-resolution electron multiplier, was used as an ion-counting setup for isotopes that either were affected by strong isobaric contamination or possessed a long half-life; the ISOLDE Faraday cups were used for cases with high-intensity beams; and the Windmill decay station was used for short-lived, predominantl…
Construction of large-area micro-pattern gaseous detectors
2016
Particle physics experiments often comprise tracking detectors with areas of up to a few square meters. If a spatial resolution of the order of 100μm and high-rate capability are required, Micro Pattern Gaseous Detectors (MPGD) are a cost-effective solution. However, the construction of large-area MPGDs is challenging, since tight fabrication tolerances have to be met to guarantee a stable and homogeneous performance. A precision granite table and an automated 3-D positioning system with an attached laser sensor, both inside a laminar-flow cell, have therefore been set up in the PRISMA Detector Lab at Mainz. Currently, this infrastructure is used to produce drift panels for the upgrade of t…
Performance studies of the P¯ANDA planar GEM-tracking detector in physics simulations
2018
Abstract The P ¯ ANDA experiment will be installed at the future facility for antiproton and ion research (FAIR) in Darmstadt, Germany, to study events from the annihilation of protons and antiprotons. The P ¯ ANDA detectors can cover a wide physics program about baryon spectroscopy and nucleon structure as well as the study of hadrons and hypernuclear physics including the study of excited hyperon states. One very specific feature of most hyperon ground states is the long decay length of several centimeters in the forward direction. The central tracking detectors of the P ¯ ANDA setup are not sufficiently optimized for these long decay lengths. Therefore, using a set of the planar GEM-trac…
Messungen zur Ansprechwahrscheinlichkeit und Impulshöhenverteilung eines Sekundärelektronenvervielfachers
1966
The pulse height distribution of a CuBe-secondary electron multiplier has been investigated under the action of single electrons. For an energy interval from 150 eV to 1000 eV the maximum pulse height increases with increasing electron energy (the energy corresponding to maximum yield being 365±10 eV). This shows the statistics of secondary electron emission as being dependant on primary electron energy.
Untersuchung verschiedener Elektronenemissionsprozesse auf Mehrfachemission
1965
A comparison of the pulse hight distribution of several electron emission processes is drawn. Thermionic electrons, photoelectrons, field electrons and exoelectrons are found to be emitted as single electrons.
Aging measurements with the gas electron multiplier (GEM)
2001
Abstract Continuing previous aging measurements with detectors based on the Gas Electron Multiplier (GEM), we investigated a 31×31 cm 2 triple-GEM detector, as used in the small area tracking of the COMPASS experiment at CERN. With a detector identical to those installed in the experiment, long-term high-rate exposures to 8.9 keV X-ray radiation were performed to study its aging properties. In standard operation conditions, with Ar/CO2 (70:30) gas filling and operated at an effective gain of 8.5×103, no change in gain and energy resolution is observed after collecting a total charge of 7 mC / mm 2 , corresponding to seven years of normal operation. This observation confirms previous results…